STEP 25
Turn o supply power before wiring ALL300RM. Turn o light switch in square box. Wire light switch
with 110V wiring. e 110V light switch leg can not be used as motor feed. Keep light and motor neutrals
separate. e light neutral is white and 10 gauge. If wired properly, a dimmer may be used. See Diagram O.
Wire Light Circuits on seperate phases (2 hots - 1 neutral).
Never wire the ALL300RM improperly. Make sure electricity is turned o when installing and/or
performing maintenance on the ALL300RM. Improper wiring and/or electricity could cause death,
personal injury, and/or property damage.
10 awg
Light Neutral
14 awg
Motor Neutral
14 awg
Motor Hot
110V Incoming
Hot For Motor
110V
Incoming
Hot for Light
Circuit 1
Diagram O
110V
Incoming
Hot for Light
Circuit 2
Black
12 awg
Light Hot
Circuit 1
Red
12 awg
Light Hot
Circuit 2
Vue de la page 13