ALL1000RM TROUBLESHOOTING GUIDE cont.
1. Conrm ALL1000RM is at the CEILING POSITION. If not, use the controller to operate the
ALL1000RM to the CEILING POSITION. Chandelier will only light at the CEILING POSITION. If
operated to the CEILING POSITION and the chandelier will still not light, proceed to step 2.
2. Conrm light switch in the square box is turned on. e square box is mounted on the chassis plate of
the ALL1000RM, right in front of the control board. If it was found in the o position, ip it to the on
position and to test the chandelier. If chandelier still does not light, proceed to step 3.
3. Turn the motor and light switch in the square box to the o position. Conrm light fuse is good. e
light fuse is held to the control board by fuse clips and is located right in front of the light relay. Remove
and perform a continuity test on the light fuse. If the fuse reads continuity, place it back in the fuse clips.
If it does not read continuity, it must be replaced with a new, indentical amperage, fast blow fuse. Turn the
motor and light switch in the square box to the on position, and test the chandelier. If the chandelier still
does not light, proceed to step 4.
4. From where the ALL1000RM is installed, call Aladdin Light Lift technical support Monday through
Friday during normal business hours at (877) 287-4601. A voltage meter will be needed to further test the
ALL1000RM.
SYMPTOM: ALL1000RM WILL NOT SHUT OFF PROPERLY AT CEILING
POSITION:
Discontinue use immediately and contact Aladdin Light Lift at (877) 287-4601.
After all troubleshooting is complete, replace control board cover.
WHITE
OR
PURPLE
GREEN OR ORANGE
RED OR BROWN
Replace with same type (ABC)
same amp, fast acting fuse:
ALL200-15A,250V ALL700-20A,250V
ALL300-15A,250V ALL1000-20A,250V
White or Purple (COMMON)
Green or Orange (NO)
Red or Brown (NC)
Replace with same type (GDC)
same amp, slow blow fuse:
ALL200-1.6A,250V ALL700-1.6A,250V
ALL300-1A,250V ALL1000-1.6A,250V
NOTE:
When installing a new circuit board, please see the
key below for the wiring of the limit switch wire to
the new circuit board:
COM = WHITE OR PURPLE WIRE
NO = GREEN OR ORANGE WIRE
NC = RED OR BROWN WIRE
Limit switches must be wired as seen in diagram below. If not wired correctly, this could