STEP 25
Turn o supply power before wiring ALL200RM light switch. Turn o light switch in square box. Wire
light switch with 230V wiring. e 230V light switch leg can not be used as motor feed. Keep light and
motor hots separate. One light hot is black and 12 gauge. e other is white and 12 gauge. If wired
properly, a dimmer may be used. See Diagram O.
Never wire the ALL200RM improperly. Make sure electricity is turned o when installing and/or
performing maintenance on the ALL200RM. Improper wiring and/or electricity could cause death,
personal injury, and/or property damage.
Aladdin 12 Gauge Light Hot
(White)
Aladdin 12 Gauge Light Hot
(Black)
House Hot Light
Switch Leg 230V
House Hot Light
Switch Leg 230V
Diagram O