STEP 13
Remove dust cover and remove paper tape from winch drum while keeping tension on winch cable.
Never operate the ALL1000 without tension on the cable. Never remove or tamper with the cable safety
device. Never install an ALL1000 that has the cable safety device removed or tampered with. e cable
safety device consists of the limit switch and small gauge rectangular wire. It is located directly in front
of the winch drum. Removing or tampering with the cable safety device could cause the cable to become
reversed wrapped on the winch. is could also cause the cable to unravel o the winch drum and get
damaged. Never install or operate an ALL1000 that has a frayed, kinked, or otherwise damaged cable.
Never operate the ALL1000 without rst removing the paper tape from the winch drum. Avoiding any
of these safety warnings could cause the chandelier to fall, which could cause death, personal injury, and/
or property damage.
STEP 14
Replace dust cover and locate controller wire. Controller wire is a low voltage, gray sheathed, four conductor
wire with white plugs on either end.
STEP 15
Run controller wire in to single gang box for SmartLift Controller. Chandelier must be visible from
controller location.
STEP 16
Plug controller to controller wire. Use supplied cover plate screws to attach controller to single gang box.
STEP 17
Test motor and automatic shut-o system of ALL1000. For operation instruction, reference SmartLift
Controller Guide, then follow below:
Operate ALL1000 down a few inches. Operate ALL1000 up to CEILING POSITION. When ALL1000
pulls bottom contact plate and temporary weight to CEILING POSITION, the motor will, if installed and
mounted properly, shut o by itself.
Call Aladdin Light Lift (877) 287-4601 immediately if ALL1000 does not shut o at CEILING
POSITION.
Never extend the full length of winch cable from the ALL1000. is could cause the cable to become
reverse wrapped on the winch. An ALL1000 installed with a reverse wrapped cable can cause the
chandelier to fall, which could cause death, personal injury, and/or property damage. Refer to the
Keyswitch or SmartLift Controller tag for correct operating instructions. Winch cable length can
be found on the ALL1000 product sticker, shipping box and the front page of these installation
instructions.
STEP 18
Run ALL1000 down until temporary weight is at desired elevation to hang chandelier.
STEP 19
Holding tension on cable, unscrew weight from xture coupler.
Never operate the ALL1000 without tension on the cable. is could cause the cable to wind o the
winch drum and get damaged. A damaged cable could cause the chandelier to fall, which could cause
death, personal injury, and/or property damage.